Modul quvvat manbai funktsiyasi

 

Chiqish kuchlanishini sozlash
TRIM yoki ADJ (sozlanishi) chiqish pinlari bo'lgan modul quvvat mahsulotlari uchun ular REM terminali orqali boshqarilishi mumkin. Ikkita umumiy boshqaruv usuli mavjud: (1) REM ga ulangan - VIN (mos yozuvlar), masofadan boshqarish pulti o'chirilgan, VREF<0.4V required. REM suspended or connected to+VIN, module working, VREM>1V kerak. (2) REM VIN ga ulangan, masofadan boshqarish pulti o'chirilgan, VREM<0.4V is required. REM is connected to+VIN, the module operates, and VREM is required to be greater than 1V. REM hovering, remote control shutdown, also known as "hovering shutdown" (- R). If the control needs to be isolated from the input end, a optocoupler can be used to transmit the control signal.


Modullarning kombinatsiyasi
(1) Parallel kengayish. Xuddi shu modulning chiqish terminallarining parallel ulanishi chiqish quvvatini oshirishi mumkin, ammo parallel modullarning chiqish kuchlanishi nisbiy oqim almashinuvini ta'minlash va keraksiz tebranishlardan qochish uchun nisbatan bir xilda sozlanishi kerak. Yuqori oqim chiqishi bo'lgan modullar uchun qo'rg'oshin qarshiligi ham joriy almashish effektiga erishish uchun ehtiyotkorlik bilan ishlab chiqilishi mumkin. Ushbu usul yordamida parallel ravishda ulangan modullar soni 2 dan oshmasligi kerak. Ayni paytda, agar modullardan biri noto'g'ri ishlasa, butun tizim to'g'ri ishlamaydi. Parallel kengaytirish ulanish sxemasi RL - yuk.


(2) parallel ravishda ortiqcha issiq zaxira. Xuddi shu modulning chiqish terminallarini diodlar orqali parallel ulanishi chiqish qobiliyatini oshirishi va quvvat tizimining ishonchliligini oshirishi mumkin. Printsipial jihatdan, mos keladigan chiqish signalizatsiya sxemasi bilan birlashtirilgan bo'lsa, modul ajratiladigan avtobusga joylashtirilishi kerak, shuning uchun noto'g'ri modullarni o'z vaqtida almashtirish mumkin. Ushbu usul yordamida parallel ravishda ulangan modullarda miqdor chegarasi yo'q. D odatda Schottky diodidir.


(3) Seriyani kengaytirish. Xuddi shu modulning chiqish terminallarini ketma-ketlashtirish chiqish kuchlanishini ikki baravar oshirishi va shunga mos ravishda quvvatni oshirishi mumkin va himoya qilish uchun ketma-ket chiqish terminaliga diod ulanishi kerak.


Ringflow-ning zaxira nusxasi va undan foydalanish
Ringli oqim generatori asosan telefon stantsiyasida telefon foydalanuvchilariga qo'ng'iroq qilish uchun ishlatiladi, odatda noto'g'ri holatda ishlatiladi. Tarafsizlikni ijobiy tarafkashlik va salbiy tarafkashlikka ajratish mumkin. Qo'ng'iroq oqimi tizimining ishonchliligini oshirish uchun qo'ng'iroq oqimining zaxira nusxasini yaratish kerak.

 