Shamol tezligini o'lchash asboblariga texnik xizmat ko'rsatish

Feb 05, 2022

Shamol tezligini o'lchash asboblari Anemometrga texnik xizmat ko'rsatish:

Anemometers belong to safety protection and environmental monitoring measuring instruments, and are mandatory verification measuring instruments stipulated by my country's Metrology Law. In addition to the corresponding calibration report required for factory sales, it is also required to go to the National Air-Conditioning Equipment Quality Supervision and Inspection Center or the China Academy of Building Research Building Energy and Energy and Environmental Engineering on a regular basis every year according to the requirements of JJG (Construction) 0001-1992 "Thermal Ball Anemometer Verification Regulations". The environmental testing center performs regular calibration and adjusts all aspects of the instrument to obtain the best working condition according to the legal calibration certificate issued by it. 2 

Kundalik ma'lumotlarning aniqligini saqlashdan tashqari, kundalik parvarishlash va foydalanishda quyidagi fikrlarga e'tibor bering:

1. Yonuvchan gaz muhitida anemometrdan foydalanish taqiqlanadi.

2. Anemometr zondini yonuvchi gazga solish taqiqlanadi. Aks holda, yong'in yoki portlash sodir bo'lishi mumkin.

3. Iltimos, yo'riqnomaning talablariga muvofiq anemometrdan to'g'ri foydalaning. Noto'g'ri foydalanish elektr toki urishi, yong'in va sensorning shikastlanishiga olib kelishi mumkin.

4. Foydalanish vaqtida anemometrdan g'ayritabiiy hid, tovush yoki tutun chiqsa yoki suyuqlik anemometrga oqib tushsa, iltimos, darhol o'chiring va batareyani chiqarib oling. Aks holda, elektr toki urishi, yong'in va anemometrning shikastlanishi xavfi mavjud.

5. Zond va anemometr korpusini yomg'irga qo'ymang. Aks holda, elektr toki urishi, yong'in va shaxsiy jarohatlar xavfi mavjud.

6. Prob ichidagi sensor qismiga tegmang.

7. Anemometr uzoq vaqt ishlatilmasa, ichki batareyani chiqarib oling. Aks holda, batareya oqishi mumkin, bu esa anemometrga zarar etkazishi mumkin.

8. Anemometrni yuqori harorat, yuqori namlik, chang va to'g'ridan-to'g'ri quyosh nuri tushadigan joyga qo'ymang. Aks holda, ichki qismlarga zarar etkazilishi yoki anemometrning ishlashi yomonlashishi mumkin.

9. Anemometrni uchuvchi suyuqlik bilan artmang. Aks holda, anemometr korpusi deformatsiyalanishi va rangi o'zgarishi mumkin. Anemometr yuzasida dog'lar paydo bo'lganda, uni yumshoq mato va neytral yuvish vositasi bilan artib tashlash mumkin.

10. Anemometrni tushirmang yoki bosim o'tkazmang. Aks holda, anemometrning noto'g'ri ishlashi yoki shikastlanishiga olib keladi.

11. Anemometr zaryadlanganda probning sensor qismiga tegmang. Aks holda, o'lchov natijasi ta'sir qiladi yoki anemometrning ichki sxemasi buziladi.