+86-18822802390

Illuminometrning yorug'lik intensivligi

Aug 08, 2023

Illuminometrning yorug'lik intensivligi

 

Luminous intensity (Candlepower): Luminous intensity, abbreviated as luminosity, refers to the luminous flux emitted from a solid angle of a light source (unit: sr), which is the density distribution of the luminous flux emitted by the light source or lighting fixture in a selected direction in space, in candlelight (cd). A light source with a luminous intensity of 1cd can emit a luminous flux of 12.57lm. Luminance: The density of the luminous flux received on the illuminated plane, measured by the luminous flux per unit area. A light flux of 1lm is evenly distributed on a surface of 1 square meter (m2), resulting in an illuminance of 1 lux (environmental technology>illuminometr); 1 lm yorug'lik oqimi 1 kvadrat fut (ft2) sirtga tushadi va uning yorug'lik qiymati 1 fut sham (fc) dir.


Yorqinlik, Yorqinlik: Biror kishining ko'zlari biror narsani ko'rganda, uni ikki yo'l bilan ifodalash mumkin: birinchidan, u yorug'lik manbai yoki chiroq kabi yuqori yorug'lik qiymatlari uchun ishlatiladi va uning yorug'lik intensivligi bilan bevosita ifodalanadi; Ikkinchisi yorug'lik chiqarmaydigan, faqat yorug'likni aks ettiradiganlar uchun ishlatiladi, masalan, ichki yuzalar yoki yorqinlikda ifodalangan umumiy ob'ektlar. Yorqinlik - ob'ektning yorqinligidagi farqni ko'rsatish uchun ishlatiladigan, ma'lum bir yo'nalishda ob'ektning birlik maydoniga chiqadigan yoki aks ettirilgan yorug'lik intensivligini anglatadi. Metrik birlik kandela/kvadrat metr (cd/m2) yoki nit, ingliz birligi esa Footlambert (fl).


Ko'zgu yoki aks ettiruvchi omil: sirtning yorqinligi unga tushadigan yorug'lik miqdori va sirtning yorug'likni aks ettirish qobiliyatiga bog'liq; Uning aks etishi mumkin bo'lgan yorug'likning miqdori va tarqalishi material yuzasining xususiyatlariga bog'liq bo'lib, aks ettirilgan yorug'lik va tushayotgan yorug'lik nisbati bilan ifodalanadi. Qora sirtning aks ettirish nisbati yoki material sirtining aks etishi (foiz) deb ataladigan ko'rsatkich {{0}} ga teng, ya'ni unga qanchalik yorug'lik tushmasin, yorqinlik yo'q. hosil bo'ladi va u butunlay so'riladi; Aksincha, * * oq yuzaning aks etishi 1 ga teng (aks etish 100 foiz, yutilish 0 foiz). Ko'zguni o'lchash uchun avval illuminometrni ob'ekt yuzasiga qo'ying va uning sirt yoritilish qiymatini o'qing Ei (Incidentlight), so'ngra yorug'lik qiymatini 5-8sm yuqoriga qo'ying (yorug'lik sezgir qismi sirtga qaragan holda va yorug'likni ta'minlang. soya to'siqsiz) uning aks ettirilgan yorug'lik qiymatini o'lchash uchun Er (Reflectedlight). Sirt yoritilishining aks ettirilgan yorug'likka bo'linishi material sirtining aks etishidir.

 

Photometer -

 

 

So'rov yuborish